Controller N2000
NOVUS AUTOMATION 6/9
CONFIGURATION CYCLE
type
typetype
type
INPUT TYPE: Selects the input signal type to be connected
to the process variable input. Refer to Table 1.
This is the first parameter to be set.
dppo
dppodppo
dppo
DECIMAL POINT POSITION: For input types 16, 17, 18 or
19 only. Selects the decimal point position to be viewed in
both PV and SV.
vn
vnvn
vnI
II
It
tt
t
TEMPERATURE INDICATION IN ºC OR ºF: Selects the
display indication to be in ºC or ºF. Only available if input type
is other than 16, 17, 18 or 19.
offs
offsoffs
offs
SENSOR OFFSET: Offset value to be added to the PV to
compensate sensor error. Default value: zero.
spll
spllspll
spll
SET POINT LOW LIMIT:
- Linear inputs: Sets the lower range for SV and PV indication.
- T/C and Pt100 inputs: sets the lower range for SV.
spxl
spxlspxl
spxl
SET POINT HIGH LIMIT:
- Linear inputs: Sets the upper range for SV and PV indication.
- T/C and Pt100 inputs: sets the upper range for SV.
rsll
rsllrsll
rsll
REMOTE SET POINT LOW LIMIT: Selects the lower range
for indication of the Remote Setpoint.
rsxl
rsxlrsxl
rsxl
REMOTE SET POINT HIGH LIMIT: Selects the upper range
for indication of the Remote Setpoint.
bavd
bavdbavd
bavd
DIGITAL COMMUNICATON BAUD RATE SELECTION:
0: 1200bps; 1: 2400bps; 2: 4800bps; 3: 9600bps; 4: 19200bps.
addr
addraddr
addr
SLAVE ADDRESS SELECTION: Identifies a slave in the
network. The possible address numbers are from 1 to 247.
I/O CYCLE (INPUTS AND OUTPUTS)
I
II
Io 1
o 1o 1
o 1
I/O 1 FUNCTION: Selects the I/O function to be used at I/O 1
(relay 1). Options 0 to 5 are possible for this output. It is
normally used as option 5, PWM main control output. Refer to
Table 2 for functions.
I
II
Io 2
o 2o 2
o 2
I/O 2 FUNCTION: Selects the I/O function to be used at I/O 2
(relay 2). Options 0 to 5 are available. This output is normally
used as alarm output. See Table 2 for functions.
I
II
Io 3
o 3o 3
o 3
I/O 3 FUNCTION: Selects the I/O function to be used at I/O 3
(option 1). I/O 3 can be a relay output or a digital input/output.
Functions 0 to 10 are available. Refer to Table 2 for
functions. The presence of this I/O option is detected by the
controller and the prompt menu will only be shown if the
expansion option is available.
I
II
Io 4
o 4o 4
o 4
I/O 4 FUNCTION: Selects the I/O function to be used at I/O 4
(option 2). I/O 4 can be a digital input/output. Functions 0 to
10 are available. Refer to Table 2 for functions. The prompt
menu will only be shown if the expansion option is present.
I
II
Io 5
o 5o 5
o 5
I/O 5 FUNCTION: Selects the I/O function to be used at I/O 5
(Analog Output). Functions 0 to 15 are available (See Table
2). This option is normally used for main control output or PV
analog retransmission.
I o 6
I o 6I o 6
I o 6
I/O 6 FUNCTION: Selects the I/O function to be used at I/O 6
(Digital Input). Options 0, 6, 7, 8, 9 and 10 are possible for
this input. Refer to Table 2 for functions.
f.fvnc
f.fvncf.fvnc
f.fvnc
F KEY FUNCTION: Selects the I/O function assigned to the
front panel
F
key. Available functions are:
0
00
0 - Key not used;
7
77
7 - Start/Stop the controller (RUN function);
8
88
8 - Select remote setpoint;
9
99
9 - Execute/Hold ramp and soak profile;
10
1010
10- Enable/Disable ramp and soak profile 1;
Details on these functions are described in section 5.2.
aven
avenaven
aven
ENABLE THE
key Enable or disable operation of the
key.
Yes
YesYes
Yes
key enabled.
NO
NONO
NO
key disabled.
CALIBRATION CYCLE
All input and output types are factory calibrated. This cycle should
only be accessed by experienced personnel. If in doubt do not press
the or keys in this cycle.
Inl(
Inl(Inl(
Inl(
INPUT LOW CALIBRATION: Sets the Process Variable low
calibration (offset). Several keystrokes at or
might be
necessary to increment one digit.
Inx(
Inx(Inx(
Inx(
INPUT HIGH CALIBRATION: Sets the Process Variable span
calibration (gain).
ovll
ovllovll
ovll
OUTPUT LOW CALIBRATION: Sets the analog current
output low calibration (offset).
Ovx(
Ovx(Ovx(
Ovx(
OUTPUT HIGH CALIBRATION: Sets the analog current
output span calibration (gain).
(j l
(j l(j l
(j l
COLD JUNCTION OFFSET CALIBRATION: Sets the cold
junction offset calibration.
Rsl(
Rsl(Rsl(
Rsl(
REMOTE SET POINT LOW CALIBRATION: Sets the
Remote Set Point low calibration (offset). Several keystrokes
at or
might be necessary to increment one digit.
Rsx(
Rsx(Rsx(
Rsx(
REMOTE SET POINT HIGH CALIBRATION: Sets the
Remote Set Point span calibration (gain).
Table 10 shows the sequence of cycles and parameters presented in the indicator display. There are parameters that must be defined for each
alarm available.
OPERATION CYCLE AUTO TUNING CYCLE PROGRAMMING CYCLE ALARM CYCLE CONFIGURATION CYCLE
I/O CYCLE
PV and SP
Atvn
AtvnAtvn
Atvn
Tbas
TbasTbas
Tbas
Fva1
Fva1Fva1
Fva1 - fva4
fva4fva4
fva4
type
typetype
type
Io 1
Io 1Io 1
Io 1
Avto
AvtoAvto
Avto
Pb
PbPb
Pb
Prn
PrnPrn
Prn
Bla1
Bla1Bla1
Bla1 - bla4
bla4bla4
bla4
Dp.po
Dp.poDp.po
Dp.po
Io 2
Io 2Io 2
Io 2
PV and MV
Ky.st
Ky.stKy.st
Ky.st
ptol
ptolptol
ptol
Kya1
Kya1Kya1
Kya1 - kya4
kya4kya4
kya4
Vnit
VnitVnit
Vnit
Io 3
Io 3Io 3
Io 3
prn
prnprn
prn
ir
irir
ir
Psp0
Psp0Psp0
Psp0 - PsP7
PsP7PsP7
PsP7
A1t1
A1t1A1t1
A1t1
offs
offsoffs
offs
Io 4
Io 4Io 4
Io 4
rvn
rvnrvn
rvn
dt
dtdt
dt
Pt1
Pt1Pt1
Pt1Pt7
Pt7Pt7
Pt7
A1t2
A1t2A1t2
A1t2
Spll
SpllSpll
Spll
Io 5
Io 5Io 5
Io 5
(t
(t(t
(t
Pe1
Pe1Pe1
Pe1Pe7
Pe7Pe7
Pe7
A2t1
A2t1A2t1
A2t1
spkl
spklspkl
spkl
Io 6
Io 6Io 6
Io 6
Act
ActAct
Act
lp
lplp
lp
A2t2
A2t2A2t2
A2t2
rsll
rsllrsll
rsll
f.fvnc
f.fvncf.fvnc
f.fvnc
bias
biasbias
bias
rskl
rsklrskl
rskl
aven
avenaven
aven
Table 10